ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView)
Specifications | |
---|---|
Product Category: | Exosome Labeling for Nanoparticle Tracking Analysis |
Product Description
- Specifically label EVs for fluorescent NanoSight NTA quantitation
- Proprietary dye for high signal-to-noise ratio
- Compatible with common EV isolation methods including ExoQuick™, ultracentrifugation, and column-based methods
- 20-minute protocol from sample isolation to analysis
Building upon ExoGlow-NTA, a proprietary dye that enables fluorescent NTA analysis of only the extracellular vesicles present in a heterogenous sample, SBI has developed a new version compatible with Particle Metrix’s ZetaView® instrument. The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) provides accurate EV NTA data that excludes protein aggregates, membrane fractions, and other background particles to provide EV-specific particle size and concentration.
Gain more accurate insight into your exosome sample
The new ExoGlow-NTA Fluorescent Labeling Kit (for Particle Metrix ZetaView) takes advantage of the fluorescence capabilities of the ZetaView NTA instrument with a proprietary fluorescent dye, which works by reacting specifically and efficiently to the surface of intact vesicles. Membrane fragments, protein aggregates, and other background particles do not activate the ExoGlow-NTA dye, resulting in exclusion of these species from fluorescent NTA analysis (Figure 1). Thus, with the ExoGlow-NTA Kit, the data delivered by ZetaView more accurately represents the EV populations in your sample rather than all particles, as is typically reported by conventional (non-fluorescent) NTA.
Figure 1. The ExoGlow-NTA dye only binds to membranes of intact EVs. Unlike conventional NTA, which collects data on all particles in a solution based on light scattering, the fluorescence mode of the NanoSight instrument selectively detects the labeled EVs and only the data from fluorescently-labeled particles is reported.
Supporting Data
SBI’s ExoGlow-NTA Fluorescent Labeling Kit delivers highly accurate EV quantitation in a quick and easy workflow. The proprietary dye offers highly efficient labeling (Figure 2), very low background (Figure 3), and is compatible with a wide range of EV isolation techniques.
Figure 2. ExoGlow-NTA-labeled liposomes deliver consistent NTA data whether in light scattering or fluorescent mode. The high concordance of NTA and fluorescent NTA data collected from the ExoGlow-NTA Kit internal standards (ExoGlow-NTA-labeled synthetic liposomes) demonstrates the labeling efficiency of the ExoGlow-NTA Dye and accuracy of the fluorescent NTA method for characterizing EVs.
Figure 3. ExoGlow-NTA delivers undetectable background signal. When analyzing the ExoGlow-NTA dye alone in PBS, conventional NTA picks up background particles in the absence of EVs, while fluorescent NTA of the ExoGlow-NTA dye alone shows bias-free undetectable autofluorescence.
Kit Contents
The ExoGlow-NTA Fluorescent Labeling Kit comes with three components: 1) Labeling dye 2) Standard and 3) Reaction Buffer. Simply mix the dye with the reaction buffer, add 1-100 µg of EVs (or protein equivalent), incubate for 5 minutes, and you are ready for fluorescent NTA analysis. The provided Internal Standards are size-controlled synthetic liposomes that provide a positive control for NTA calibration as well as EV/exosome labeling efficiency using the ExoGlow-NTA Kit.
Fluorescent NTA Analysis Service
Don't have access to a NanoSight instrument equipped with the 488nm laser? We also offer fluorescent NTA as a service, simply send us your samples.
- Catalog Number
EXONTA110A-1-SBI - Supplier
SBI System Biosciences - Size
- Shipping
Blue Ice