5-Formylcytosine DNA Quantification Assays

The MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric) is a complete set of optimized buffers and reagents to colorimetrically quantify 5-formylcytosine (5-fC) in a microplate-based format. It is suitable for use with DNA isolated from any species (mammals, plants, fungi, bacteria, viruses, etc.) in a variety of forms including, but not limited to, cultured cells, fresh and frozen tissues, paraffin-embedded tissues, and body fluid samples. The kit has the following advantages and features:

• Fast and easy procedure completed within just 3 hours and 45 minutes
• High sensitivity, of which the detection limit can be as low as 1 pg of 5-fC
• High specificity with detection of only 5-fC. No cross-reactivity to cytosine, 5-mC, 5-hmC, or 5-caC within the indicated concentration range of the sample DNA
• Highly convenient assay that uses DNA isolated from cells or tissues directly; no need for DNA digestion or hydrolysis
• Universal positive and negative controls are included, which are suitable for quantifying 5-fC from any species
• Strip-well microplate format makes the assay flexible: manual or high throughput analysis
• Simple, reliable, and consistent assay conditions

Image
Fig. 1. Schematic procedure for the MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric).

Background Information
5-formylcytosine (5-fC) has recently been found in mammalian tissue and cells and has been classified as a seventh DNA base. It is formed by the oxidation of 5-hydroxymethylcytosine through TET hydroxylases and has been demonstrated to be an intermediate of the DNA demethylation process. The function of 5-fC in gene regulation is not yet entirely clear, but it has been shown that 5-fC exhibits replication-dependent dilution during mouse pre-implantation development and could be functional in regulating pre-implantation development as a whole. The detection of 5-fC in various tissues and cells is important because 5-fC could be a marker to indicate active DNA demethylation. 5-fC can also be directly excised by Thymine DNA glycosylase (TDG) to allow subsequent base excision repair (BER) processing which converts modified cytosine back to its unmodified state.

Several chromatography-based techniques such as HPLC-MS are used for the detection of 5-fC in tissue and cells. However, these methods are time consuming, require large amounts of DNA and have low throughput with high costs. To address these problems, Epigentek offers the MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric), which uses a unique microplate-based procedure to directly quantify 5-fC.

Principle & Procedure
The MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric) contains all the reagents necessary for the quantification of 5-fC. In this assay, DNA is bound to strip-wells that are specifically treated to have a high DNA affinity. 5-fC is detected using capture and detection antibodies. The detected signal is enhanced and then quantified colorimetrically by reading the absorbance in a microplate spectrophotometer at a wavelength of 450 nm. The amount of 5-fC is proportional to the OD intensity measured.

Starting Materials & Input Amount
The detection limit of the input DNA can be as low as 1 pg of 5-fC with a dynamic range from 10 pg to 400 pg (see Fig. 2). There is no cross-reactivity to cytosine, 5-mC, or 5-hmC within the indicated concentration range of the sample DNA (see Fig. 3).

Image
Fig. 2. 5fC standard control was added into the assay wells at different concentrations and then measured with the MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric).


Image
Fig. 3. Demonstration of high specificity of 5fC detection achieved by the MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric). Synthetic unmethylated DNA, methylated DNA, hydroxymethylated DNA and 5-formylcytosine DNA standard were added into the assay wells at different concentrations and then measured with the MethylFlash™ 5-Formylcytosine DNA Quantification Kit (Colorimetric).

Safe and Convenient
All the necessary reagents, including negative and positive controls, for the quantification of 5-fC are conveniently packaged in the kit. The direct colorimetric quantification of DNA samples in a 96-well microplate format eliminates the need for DNA digestion/denaturation, radioactivity, extraction, or chromatography.

Easy, Fast, and Flexible
The entire colorimetric assay has easy-to-follow steps for convenience and speed, allowing it to be completed in just 3 hours and 45 minutes. The strip-well microplate format allows for a flexible assay for manual or high throughput analysis. Universal positive and negative controls are included with the kit for the quantification of 5-fC from any species, such as mammals, plants, fungi, bacteria, and viruses.

Responsive, Reliable, and Practical
Based on its working principle and the microplate format, the kit can be practically and routinely used for any species and for a variety of forms including cultured cells, fresh and frozen tissues, and paraffin-embedded tissues. To demonstrate the capabilities of the kit, it has been successfully used for quantifying the content of 5-fC in DNA from human brain tissue, mouse brain tissue, rectal tissue, and rectal cancer. The percentage of 5-fC measured by the kit is parallel and comparable to that detected by LC-MS/MS methods (see Fig. 4).

Image
Fig. 4. Percentage of 5fC in different tissues measured with the MethylFlash™ 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric).
Related Links

MethylFlash™ Methylated DNA Quantification Kits
MethylFlash™ Hydroxymethylated DNA Quantification Kits

 

 

Description Cat# Size Price    
MethylFlash 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric) P-1041-48-EP 48 assays 466 € DETAILS   Add to Cart 
MethylFlash 5-Formylcytosine (5-fC) DNA Quantification Kit (Colorimetric) P-1041-96-EP 96 assays 729 € DETAILS   Add to Cart 

DNA and RNA Purification

Bioline

Use ISOLATE II Nucleic Acid Isolation Kits for the purification of high-quality DNA and RNA.

BioCat Spring Special

Spring Special

10% OFF
3'UTR microRNA Target & Promoter Analysis

Email Newsletter

Subscribe to the BioCat Email Newsletter.

Clone Resources

BioCat Clone Resources

Browse two of the most renowned clone resources of full-length cDNA, ORF, and shRNA clones as well as siRNA and yeast knockout strains.

Genome Engineering

Genome Engineering

Use the CRISPR/Cas9 SmartNuclease System to edit the genome.

ExoQuick and ExoQuick-TC

ExoQuick Exosome Isolation

Benefit from the most cited exosome isolation reagent for efficient exosome isolation and exosomal RNA purification from biofluids or culture media.

Home
Imprint / Impressum | Privacy Policy / Datenschutzerklärung
Top of Page Up!